FRAEW and PAS 9980 assessments in Central London

A fire risk appraisal of external walls assesses the risk of external fire spread for an existing multi-storey, multi-occupied residential building using the PAS 9980 methodology where that appraisal is appropriate. It considers the whole wall system and building context, not cladding material in isolation.

Central LondonFire Safety & FacadeRICS Regulated
Scope the Decision

Choosing FRAEW and PAS 9980 assessments in Central London

A fire risk appraisal of external walls assesses the risk of external fire spread for an existing multi-storey, multi-occupied residential building using the PAS 9980 methodology where that appraisal is appropriate. It considers the whole wall system and building context, not cladding material in isolation.

Good fit

Choose an FRAEW when competent screening indicates that external-wall construction presents known or suspected fire-spread questions requiring a structured risk appraisal.

Choose another route when

It is not an EWS1 lender form, general facade condition survey, product-compliance certificate or automatic instruction to remove cladding; those decisions require their own evidence and purpose.

Who and What

Clients and Central London property covered

Typical clients

  • Responsible persons
  • Freeholders and managing agents
  • Housing providers
  • Remediation project teams

Relevant property and asset types

  • Multi-occupied residential blocks
  • Mixed-use blocks with homes
  • Clad apartment buildings
  • Buildings with balconies or facade attachments
Local Application

Central London issues that shape this service

Evidence across every wall type

Central London buildings may combine several wall types, infill panels, balconies and later modifications, all of which need a reliable evidence trail and representative investigation.

Risk-led intrusive access

Constrained elevations and occupied premises can make intrusive opening-up difficult, so locations must be selected for risk relevance rather than convenience alone.

Whole-building fire-risk context

Fire-service access, escape strategy and internal fire precautions form part of the wider risk context and should not be ignored in a material-only assessment.

Heritage after risk appraisal

Heritage or planning sensitivity can influence remediation options after appraisal but does not predetermine the life-safety risk category.

Instruction and Output

What we need and what you receive

Useful information at instruction

  • Building address, height, use, storeys and occupancy
  • Current FRA, fire strategy, plans and external-wall records
  • Product, installation, test and previous intrusive-survey evidence
  • Access plan for all wall systems, balconies and relevant internal areas

Deliverables

  • A scoped FRAEW report following the applicable PAS 9980 methodology
  • An evidence-quality statement and description of all assessed wall systems
  • A reasoned external-wall risk conclusion with proportionate actions
  • Clear recommendations for investigation, management or remediation where needed
Process

How the Central London instruction progresses

1. Confirm the need

Existing information and the building's wall construction are screened to decide whether an FRAEW is the appropriate next assessment.

2. Plan the evidence

Wall zones, records, openings and specialist input are selected to address uncertainty across the full building.

3. Appraise risk

Construction evidence is considered with fire spread, occupant harm, escape and fire-service context under the methodology.

4. Set proportionate action

The report explains the conclusion, uncertainty and measures needed without treating risk appraisal as a lender form.

Primary Guidance

Authoritative sources for this service

These primary sources frame the statutory, professional or technical context. The property-specific scope and current requirements are confirmed before instruction.

Service Routes

Parent and related Central London services

FAQs

FRAEW and PAS 9980 assessments Central London FAQs

Does every block of flats need an FRAEW?

No. The ordinary fire-risk process includes external walls, and some traditional low-risk construction may not need a detailed FRAEW. A competent assessor should screen the actual building and available evidence.

Is PAS 9980 a pass-or-fail test?

No. It provides a risk-based appraisal methodology. The report should explain the building-specific risk conclusion, evidence quality and proportionate actions rather than issuing a generic material pass.

Will an FRAEW automatically provide an EWS1 form?

No. FRAEW addresses fire risk and EWS1 supports valuation in relevant lending circumstances. Findings may inform an appropriately competent EWS1 signatory, but the two documents are distinct.

Discuss the Property

Discuss FRAEW and PAS 9980 assessments for a Central London property

Send the address, building type, available documents and the decision or deadline the advice must support.

Request a Consultation
Reviewed by Savas Bulduk BSc (Hons) MRICS, Director & Chartered Building Surveyor at Hampstead Chartered Surveyors & Building Consultancy. Last reviewed: July 2026.