A warehouse floor may divide two separate properties
It explains that Butler's Wharf Ltd's massive riverside range of warehouses was rebuilt from the 1870s, and that in the 1880s and 1890s the landward blocks were also rebuilt, generally to a height of 6 storeys, creating the densest warehousing in London, linked at high level by iron gangways over the narrow streets.
For an owner planning a new stair or mezzanine in a Shad Thames apartment, the first drawing should put the flat back into that larger building. Give the floor number, entrance core and the position of the opening. If the work is near a former loading bay, mark its location from inside and from outside. The neighbouring flat might be below the landing or overhead and invisible on the apartment plan.
Under the Party Wall etc. Act 1996 a party structure can include a floor separating different buildings or parts approached by separate staircases or entrances. Ask whether the designer proposes to cut a separating floor, make a bearing in a wall used by two owners or simply support a new structure entirely within one demise. A relevant section 2 operation is notified by a party structure notice under section 3. The lease plan helps identify the parties, while the structural detail says what will happen to the fabric.
Locate the proposed bearing in the conversion drawings
Common elements, according to the Tower Bridge appraisal, include yellow London stock brick as the basic construction material and roofs pitched and slated, sometimes hipped behind simple brick parapets. Load bearing brickwork is very thick, and iron wall-anchors tie massive walls to heavy load-bearing floors. Wooden sashes were often replaced later in galvanised steel, and in residential conversions loading platforms and catwalks can make distinctive balconies. Because the buildings are so high and the streets so narrow, the appraisal adds, the roofs themselves are often not apparent.
A conversion may display brick, timber or metalwork as part of its interior design. Ask which elements are original, which have been altered and what documentation supports that account. Where the owner has changed room divisions or installed a mezzanine, request the relevant drawings and completion information rather than relying on photographs of the finished space.
Compare the historic information with the conversion record. An exposed tie may still be doing structural work even if it has also become a prominent part of the interior. Ask the structural engineer to identify the load path before and after the proposed alteration. State what requires opening up and which owner's space would be entered. Obtain the evidence for that location rather than relying on a typical bay drawn somewhere else in the block.
The adjoining schedule in a tall block on a narrow street
Obtain a plan or description showing where the apartment lies within the block. Identify the external walls, roof areas and common access spaces that serve it, and ask the managing agent who can arrange entry. A ground-floor reception desk does not necessarily have authority to open roof plant areas or provide technical records.
When recording existing condition, mark the elevation and storey on a key plan. A photograph looking inward through an old loading opening and one looking outward at a balcony attachment answer different questions. Include wide views of the junction and close views of existing distortion or patched masonry. Record any feature visible only from ground level. Number the images by unit, room and face of the wall so an observation about the fifth floor is not filed against an identical bay below.
Agree with the manager how the residents of both apartments will be contacted. Protect access to the common stair and identify any doors that must remain available to residents while materials are taken through the block. Consent for a survey visit does not settle a request to use a neighbouring balcony as a working area. Give that request a drawing and proposed duration of its own.
A courtyard footing is a separate operation
An extension or a new independent support in a rear courtyard may require excavation even though the principal alteration is indoors. For section 6 put the nearest adjoining structure and foundation on the same section as the proposed dig. Depending on the distances and levels, the statutory tests may or may not be met. For a new wall on the line of junction examine section 1 separately. A tenant's apparent use of the courtyard is no substitute for establishing the boundary and relevant ownership.
In Mill Street, the conversion of New Concordia Wharf in 1982-3 was an early example of Dockland regeneration.
Southwark’s planning and listed-building decisions, building regulations and the landlord's permission for an alteration each have their own scope. Check designation and the actual approved drawings for the particular warehouse. Put the drawing issue and relevant consent beside the notice and the award so the contractor can see which documents cover the particular opening or fixing.
When a neighbour’s works appear above your flat
If the papers name the wharf but give no unit or floor, send a marked-up block plan and ask which floor or pier will be affected. Keep the signed notice and enclosures as received. Our service for adjoining owners explains responses and appointments. Let the surveyor know if high-level plaster or the underside of the shared floor will be concealed by fitted furniture when the schedule is taken.
Shad Thames party wall questions
Can the exposed brick pier be treated as part of my flat alone?
Check the lease, conversion drawings and current engineer's detail. The pier may carry a floor or wall beyond the apartment and its visible surface does not define ownership or the work permissible under the Act.
Does a consent from the managing agent cover an opening in the separating floor?
Establish the authority under which it was given and the drawings it covers. The statutory position between owners and any planning or building control requirements still have to be considered for the actual opening.
What if the neighbouring ceiling cannot be reached for a condition inspection?
Record why access was unavailable and what could be seen. Arrange a further visit if possible. A photograph from inside the works apartment cannot establish the pre-work finish in the apartment beneath it.