Measure from the rear return, not the front steps
Lambeth dates the first Lancaster Villas group to 1864–1865 and describes symmetrical semi-detached houses of two storeys above a semi-basement. Its account identifies Italianate detailing, stucco window surrounds and hipped roofs. These features describe the recorded group, not whether the lower accommodation in a particular house retains its original arrangement.
Ask for documents covering changes to basement use, external steps or connections between floors. Identify any lower external area that needs separate access, including locked gates or spaces reached through another dwelling. If moisture has been reported, provide its location and timing without treating the semi-basement position as a diagnosis.
At the start of an extension design, ask for one section from the rear of the building owner's house through the proposed footing and the nearest neighbouring structure. A raised veranda, closet return or lower flat can bring an occupied part of the next house close to the excavation. Give both horizontal separation and levels. Show how the information about the adjoining foundation was established, or identify what the designer still needs to find out.
The adjacent excavation provisions of section 6 of the Party Wall etc. Act 1996 use distances and depths in relation to the neighbouring building. The boundary fence is not the reference for those tests. Where a deeper drainage run passes the corner of a return, include it as well as the principal trench. If the front of the site is the only part measured, a section based on that survey may give the adjoining owner a misleading impression of the work at the back.
At which floor does the pair meet?
The appraisal records 33–35 Lancaster Avenue as an 1865 pair with three storeys above a semi-basement. It contrasts their taller, plainer character with the broader villas and notes brick arches and stucco balustrading to the entrances.
Explain whether rooms extend into the roof and which spaces above or below are accessible. Request conversion drawings and records of later changes affecting the flat. Keep the inspection brief specific to the actual dwelling and accessible common parts, rather than implying that entry to one floor permits examination of the entire converted house.
For a plan to enlarge a roof or open a ground floor, identify the particular wall that would be raised, cut or rebuilt. Number the proposed beam and show its bearing in the party structure. Section 2 covers specified rights concerning party structures, with a party structure notice served under section 3. Compare that with a new wall proposed at the line of junction under section 1. Give each detail its own description when both apply to the same extension.
If a converted pair has a separate lower entrance, check the ownership of the rooms reached from it. The name on the upper doorbell can help arrange a visit but is not the basis for identifying the parties entitled to notice. Supply available titles, lease plans and contacts for any shared stairs or roof space. A landlord can have relevant drawings even if a resident holds the only key to the room beside the work.
Note the features that could be compared after the works
Lambeth dates 46–92 Lancaster Avenue to 1906, recording smaller terraced houses that continued the red brick, foliage ornament and bay-window character of preceding decades.
A useful schedule of condition identifies which bay, level and adjoining room a photograph records. Start with an overall view showing the bay in relation to the entrance. Use closer views to locate repairs in stucco, cracks at the edge of a window or changes in surface finish. Where a recent lining prevents a view into a junction, describe the surface that was accessible. There is no need to assign a cause to every mark in order to make a reliable pre-works record.
The appraisal distinguishes the flat rear elevations of the 1860s villas from later south-side semis with raised rear ground floors, closet returns and verandas. It also describes changes in roof detailing and replacement coverings within the street. The rear of a house may therefore require a different access explanation from its front entrance.
Agree how to reach a raised return from below as well as from the house. Identify who controls any steps, gates or shared path required for that visit. If a future contractor needs to use the same access, set out the intended operation, dates and protection. A neighbour can agree to photographs of the garden without having agreed to the movement of materials through it.
Lambeth records for an altered house
Lambeth's adopted planning material and the street appraisal describe the area and examples of its housing. Look up the decision affecting the actual address and keep the approved plans and revision numbers. Building control, planning and a leaseholder's private consent requirements are separate from the Party Wall notice and award. If a revised scheme lowers the extension floor, send the designer's section to the surveyor before treating the earlier excavation assessment as current.
For the neighbour with the lower room
If the drawings show a conventional ground floor where you have steps down into a flat or garden, mark the discrepancy on a copy and keep the notice as delivered. Our party wall service for adjoining owners explains the available responses. Give the person arranging the schedule the entrance and floor of the affected room, together with dates when you can allow access.
Tulse Hill party wall questions
Is the surface of the lower garden a foundation level?
It is a level that can be measured, but it does not identify the underside of a footing. Label what the measurement represents and ask the engineer how the depth needed for the excavation assessment can be established.
Can an inspector see the inside of both halves of a villa in one appointment?
Confirm who controls the rooms on each side and whether one is separately let. Arrange the necessary permissions and record any denied or inaccessible areas on the inspection note.
Should the proposed lean-to roof appear on the notice plans?
Include it where its support or waterproofing will affect adjoining masonry. Show the bearing and junction at a useful scale, alongside the existing roof, so the surveyor can identify the work proposed.